| MOQ | 1 Set |
| Category | Medical |
Product Description

Function and mechanism: The electric traction device adopts the traction feedback control method. The parameter input by the operator is converted into a given signal through the control system. The motor is controlled by comparing the given signal with the sensor feedback signal. After the reducer decelerates, the torque is transmitted through the transmission The chain and the main shaft are transmitted to the drum, so that the traction rope wound on the drum emits traction. In the process of traction, the sensor detects the change of the actual traction force and feeds it back to the control system in time to increase and reduce the force in real time to achieve longitudinal traction on the patient's cervical and/or lumbar spine. Scope of application: It is used by operators with relevant medical knowledge in medical units to perform traction treatment on patients' cervical and/or lumbar spine. Product advantages: 1. The device has 8 built-in traction modes (continuous, intermittent, and repetitive 2. The equipment has emergency protection measures; 3. Traction automatic compensation function; 4. Shoulder and neck heating function; 5. Multi-dimensional and multi-functional traction: longitudinal traction, rotary traction, swing traction, angle traction;
Specifications
| 1. Digital Tube. Key operation; |
| 2. Gross weight: 137kg size: 2720mm * 720mm * 920mm; |
| 3. Net weight: 90kg size:2450mm * 600mm * 730mm; |
| 4. Built-in 8 traction modes (continuous traction mode, continuous up-stair traction mode, intermittent traction mode, intermittent up-stair traction mode, intermittent up-and-down traction mode, repeated traction mode, repeated up-stair traction mode, and repeated up and down ladder traction mode); |
| 5. The adjustable range of cervical traction force: 0~300N. The step length is 1N. When the traction force is adjusted to more than 200N, a warning will be issued and the operator will be asked to confirm; |
| 6. Adjustable range of lumbar traction: 0~990N, step length is 1N; |
| 7. The average rate of change of traction force during the gradual and regressive phases of cervical traction is 60N/s; |
| 8. The average change rate of traction force during lumbar traction in the progressive and regressive phases is 90N/s; |
| 9. The equipment has a real-time monitoring function of traction, with a tolerance of ±30N; |
| 10. Adjustable range of treatment time: 0~99min, step length is 1min; |
| 11. Adjustable range of traction phase time: 0~9min, step length is 1min; |
| 12. Adjustable range of intermittent phase time: 0~9min, step length is 1min; |
| 13. The equipment has emergency protection measures. During the traction treatment, by pressing the emergency button, the traction can be relaxed to the initial state; |
| 14.Stroke range: sliding stroke range: 0 ~ 200mm |
| 15. back plate length: 700mm, leg plate length: 1250mm |
| 16. The maximum weight of the patient that can be supported by the traction bed is 180kg. |
| 17. The maximum weight of the patient that can be supported by the traction chair is 180kg. |
| 18. The equipment has a heating mattress, and the heating function can be turned on or off separately.The maximum temperature does not exceed 41℃;Customer-centric, honesty as the foundation, result-oriented |
Detailed Images





| Warranty | 1 Year |
| Place of Origin | China |
| After-sale Service | Free Spare Parts |
| Instrument classification | Class I |
| Application | Rehabilitation Centre |
| Feature | Durable |
| Material | Stainless Steel |
| Traction modes | 8 |
| Power supply | 220V 50Hz |
| Technology | Electric traction |
| Back plate length | 700mm |
| Leg plate length | 1250mm |
| Weight | 130kg |
| Gross weight | 137kg, size: 2720mm * 720mm * 920mm |
| Net weight | 90kg, size: 2450mm * 600mm * 730mm |
| Cervical traction force adjustable range | 0~300N, step length 1N, warning when over 200N |
| Lumbar traction force adjustable range | 0~990N, step length 1N |
| Cervical traction force change rate (progressive/regressive phases) | 60N/s average |
| Lumbar traction force change rate (progressive/regressive phases) | 90N/s average |
| Traction real-time monitoring tolerance | ±30N |
| Treatment time adjustable range | 0~99min, step length 1min |
| Traction phase time adjustable range | 0~9min, step length 1min |
| Intermittent phase time adjustable range | 0~9min, step length 1min |
| Sliding stroke range | 0~200mm |
| Maximum patient weight supported by traction bed | 180kg |
| Maximum patient weight supported by traction chair | 180kg |
| Heating mattress maximum temperature | ≤41℃, can be turned on/off separately |