| MOQ | 1 Other |
| Category | Medical |
Warning/Disclaimer
This product has acquired the relevant product qualification(s)/license(s) of certain applicable country/countries.
Product Description




Specification
| Parameter | 20kw 200mA/50kw 500mA |
| Intermittent mode | 100kV ,200mA,20kW 100kV ,500mA,50kW |
| Power Voltage | Three-phase five wires 380V±38V |
| tube current | Radiography16mA~200mA Radiography16mA~630mA |
| Output Voltage | Radiography 40-125KVstep 1kV |
| resistance power | less than 0.5Ω |
| Output power | 20kW 50kW |
| Exposure Time | Radiography 0.0025s~6.4s adjustable |
| Nominal Frequency | ≥30kHz |
| Anode speed | 2800r/min |
| Anode heat capacity | 140KHU |
| Focus Small focus | 1.0mm Large focus:2.0mm |
| L*W*H of bed surface | 2100mm×825mm×650mm |
| Horizontal moving range | ≥250mm |
| Vertical moving range | ≥825mm |
| grid density | ≥40 lines/cm |
| grid ratio | 10:01 |
| Focus Distance | 100cm |
| Cassette size | 5″×7″ 8″×10″ 10″×12″ 11″×14″ 14″×17″ |

1) The HX10 high frequency digital x-ray equipment can be applied to satisfy the radiographic needs ofdifferentbody parts: head, chest, abdomen, waist, thorax, pewvis, and limbs.
2) The HX10 is also capable of serving different positions: lay decubitus, normotopia, side position, etc 3) Rich DR upgrade reserve interface; 4) Fault self-diagnosis and protection; 5) Automatic calibration of tube current; 6) X-ray tube has the function of filament dormancy; 7) Analog-digital double-loop control, simple operation,high intelligence; 8) High kV, high current, high power,strong penetration,able to handle obese patients



| Warranty | 1 Year |
| Place of Origin | Guangdong, China |
| Power Source | Electricity |
| After-sale Service | Online Technical Support |
| Shape | Linear |
| Model Number | HX10 |
| Quality Certification | CE |
| Instrument classification | Class II |
| Application | medical diagnosis |
| Shelf Life | 2 Years |
| Parameter | 20kw 200mA/50kw 500mA |
| Intermittent mode | 100kV,200mA,20kW; 100kV,500mA,50kW |
| Power Voltage | Three-phase five wires 380V±38V |
| Tube current | Radiography 16mA~200mA/Radiography 16mA~630mA |
| Output Voltage | Radiography 40-125KV step 1kV |
| Resistance power | less than 0.5Ω |
| Output power | 20kW/50kW |
| Exposure Time | Radiography 0.0025s~6.4s adjustable |
| Nominal Frequency | ≥30kHz |
| Anode speed | 2800r/min |
| Anode heat capacity | 140KHU |
| Focus | Small focus 1.0mm, Large focus 2.0mm |
| Bed surface L*W*H | 2100mm×825mm×650mm |
| Horizontal moving range | ≥250mm |
| Vertical moving range | ≥825mm |
| Grid density | ≥40 lines/cm |
| Grid ratio | 10:01 |
| Focus Distance | 100cm |
| Cassette size | 5″×7″, 8″×10″, 10″×12″, 11″×14″, 14″×17″ |