| MOQ | 1 Other |
| Category | Medical |
Warning/Disclaimer
This product has acquired the relevant product qualification(s)/license(s) of certain applicable country/countries.
Product Description




Specification
1. You can choose a full range of KW wattages to suit doctors with different demand parameters 2. There are domestic tubes and Toshiba tubes to choose from 3. Provide a special Automatic Exposure Control (AEC) function 4. Simple appearance, bull head display with screen, easy to operate 5. Clear images, suitable for shooting multiple body parts 6. Low energy consumption design: The device consumes low energy during use, extending the service life of the device 7. High safety: Meet the safety standards of medical devices to ensure the safety of patients and operators 8. Easy to maintain: The device is designed for easy maintenance and cleaning, reducing subsequent maintenance costs 9. The operation interface is simple and clear, which is convenient for medical staff to quickly get started and reduce learning costs 10. Durability: Made of high-quality materials, it has good durability and is suitable for long-term use
| Generator | Input power | 220VAC, Single phase, ±10%50/60Hz;110VAC, Single phase, ±10%50/60Hz |
| Nominal electric power | 32KW | |
| Tube current (mA) | 10-400mA | |
| Tube voltage | 40kV-150kV, 1kV step | |
| Current time product (mAs) | 0.1-160mAs | |
| Loading time (ms) | 1-6300ms | |
| Inverter frequency | 25kHz +/- 5% | |
| X-ray Tube | Focal spot | 0.5mm/1.0mm |
| Focal power | 10kW /33kW | |
| Tube voltage range | 40KV-125KV | |
| Anode heat capacity | 100kJ (140kHU) | |
| Anode target angle | 16° | |
| Rotary anode | 2800 rpm | |
| collimator | Power supply | AC/DC 24V ±10% |
| Field light | LED, 5W | |
| Collimator rotation range | 360 ° any angle | |
| Min. brightness | ≥160Lux | |
| Maximum field size | ≥430mm×430mm at SID=100cm | |
| light timer | 30±2s | |
| Radiographic Table | Mobile Type | Four-way Floating Tabletop; Foot Pedal Operated Tabletop Float |
| Table size | 2100×800mm×720mm | |
| Range of Vertical Floating | 90mm | |
| Range of Horizontal Floating | 260mm | |
| Bucky Size | 17X17inch | |
| Tube Rotation Angle Range | Manual ±180° | |
| Tube Column Rotation Range | Manual ±180° | |
| Column moves up and down | Manual | |
| Tube Column Moving Range Along Bed | 1770mm | |
| Tube Vertical movement Range | 980mm-1940mm | |
| Bucky Stand | Control mode | Manual |
| Height | ≤2250mm | |
| Lifting stroke | 1400mm, ±5% | |
| Size of Wall Stand Tray | 17X17inch |
Detailed Images




| Warranty | 2 Years |
| Place of Origin | Guangdong, China |
| Power Source | Electric |
| After-sale Service | Online Technical Support |
| Shape | Rectangular |
| Model Number | HX20 |
| Function | Radiography |
| Ambient temperature | -20°C~+70°C |
| Relative humidity | 10%~100% |
| Atmospheric pressure | 50Kpa~106Kpa |
| Nominal frequency | ≥30kHz |
| Anode speed | 2800r/min |
| Anode heat capacity | 140KHU |
| Horizontal moving range | ≥250mm |
| Quality Certification | CE |
| Instrument classification | Class II |
| Generator Input power | 220VAC, Single phase, ±10% 50/60Hz; 110VAC, Single phase, ±10% 50/60Hz |
| Nominal electric power | 32KW |
| Tube current | 10-400mA |
| Tube voltage | 40kV-150kV, 1kV step |
| Current time product | 0.1-160mAs |
| Loading time | 1-6300ms |
| Inverter frequency | 25kHz +/- 5% |
| X-ray Tube Focal spot | 0.5mm/1.0mm |
| Focal power | 10kW /33kW |
| Tube voltage range | 40KV-125KV |
| Anode target angle | 16° |
| Collimator Power supply | AC/DC 24V ±10% |
| Field light | LED, 5W |
| Collimator rotation range | 360° any angle |
| Min. brightness | ≥160Lux |
| Maximum field size | ≥430mm×430mm at SID=100cm |
| Light timer | 30±2s |
| Radiographic Table size | 2100×800mm×720mm |
| Range of Vertical Floating | 90mm |
| Range of Horizontal Floating | 260mm |
| Bucky Size | 17X17inch |
| Tube Rotation Angle Range | Manual ±180° |
| Tube Column Rotation Range | Manual ±180° |