| MOQ | 1 Other |
| Category | Medical |
Warning/Disclaimer
This product has acquired the relevant product qualification(s)/license(s) of certain applicable country/countries.
Product Description
Portable 20KW Veterinary Double Column DR X-ray Machine for Animal Hospital Pet Clinic






Specification
| Generator | Input power | 110V |
| Nominal electric power | 20KW | |
| Tube current (mA) | 10-200mA | |
| Tube voltage | 40kV-150kV, 1kV step | |
| Current time product (mAs) | 0.1-100mAs | |
| Loading time (ms) | 1 - 6300ms | |
| Inverter frequency | 50kHz±5% | |
| X-ray Tube | Focal spot | 0.5mm/1.0mm |
| Focal power | 10KW/33KW | |
| Tube voltage range | 40-125KV | |
| Anode heat capacity | 100KJ(140KHU) | |
| Anode target angle | 16º | |
| Rotary anode | 2800rpm (50Hz);3200rpm (60Hz) | |
| collimator | Power supply | AC/DC 24V ±10% |
| Field light | LED, 5W | |
| Collimator rotation range | 360 ° any angle | |
| Min. brightness | ≥160Lux | |
| Maximum field size | ≥430mm×430mm at SID=100cm | |
| light timer | 30±2s | |
| Radiographic Table | Mobile Type | Four-way Floating Tabletop; Foot Pedal Operated Tabletop Float |
| Table size | 1400x1000mmx1800mm | |
| Range of Vertical Floating | 200mm | |
| Range of Horizontal Floating | 300mm | |
| Bucky Size | 17X17inch | |
| Tube Rotation Angle Range | Fixed | |
| Tube Column Rotation Range | Fixed | |
| Column moves up and down | Fixed | |
| Tube Column Moving Range Along Bed | Fixed | |
| Tube Vertical movement Range | Fixed | |
| Bucky Stand | Control mode | Foot switch |
| Height | Fixed | |
| Lifting stroke | / | |
| Size of Wall Stand Tray | / |
| Warranty | 1 Year |
| Place of Origin | Guangdong, China |
| Power Source | Electricity |
| After-sale Service | Online Technical Support |
| Shape | Linear |
| Quality Certification | CE |
| Instrument classification | Class II |
| Application | x-ray photography |
| Shelf Life | 2 Years |
| Model Number | Pet10 |
| Generator Input power | 110V |
| Nominal electric power | 20KW |
| Tube current | 10-200mA |
| Tube voltage | 40kV-150kV, 1kV step |
| Current time product | 0.1-100mAs |
| Loading time | 1 - 6300ms |
| Inverter frequency | 50kHz±5% |
| X-ray Tube Focal spot | 0.5mm/1.0mm |
| Focal power | 10KW/33KW |
| X-ray Tube voltage range | 40-125KV |
| Anode heat capacity | 100KJ(140KHU) |
| Anode target angle | 16° |
| Rotary anode speed | 2800rpm (50Hz); 3200rpm (60Hz) |
| Collimator power supply | AC/DC 24V ±10% |
| Collimator field light | LED, 5W |
| Collimator rotation range | 360° any angle |
| Collimator min. brightness | ≥160Lux |
| Collimator maximum field size | ≥430mm×430mm at SID=100cm |
| Collimator light timer | 30±2s |
| Radiographic Table type | Mobile Type Four-way Floating Tabletop; Foot Pedal Operated Tabletop Float |
| Radiographic Table size | 1400x1000mmx1800mm |
| Radiographic Table vertical floating range | 200mm |
| Radiographic Table horizontal floating range | 300mm |
| Bucky Size | 17X17inch |
| Bucky Stand control mode | Foot switch |